  PREDICTION OF TEMPERATURE PROFILE OF A BURIED GAS PIPELINE THROUGH UTILIZATION OF CORRESPONDING STATES PRINCIPLE
 
 
M. Edalat and K. Adham

Chemical Eng. Committee
Technical and Engineering Group
Educational Programming Supreme Council
Ministry of Culture and Higher Education
Tehran, Iran
 
 
( Received: May 1988 )
 
 

Abstract    A new analytical equation for prediction of temperature profile of a buried gas pipeline is developed. Utility of this equation is illustrated by its application to corresponding states principle. The resulting equation is tested through prediction of the actual Schorre data. It is shown that the new equation can predict temperature profile more accurately than the others without using any chart of tables. This equation can also be used for prediction of gas mixture temperature profile flowing in a buried pipeline.

 
 

References   

1. Schorre, C. E., “Flow Temperature in a Gas Pipeline Oil and Gas J”, (Sept. 1954).
2. Forrest, J. A., “Interpreting the Schorre Gas Temperature Equation”, Pipe Line Industry, (Feb. 1978).
3. Coulter, D. M., “New Equation Accurately Predicts Flowing Gas Temperature”.
4. Arpaci, V. S., “Conduction heat Transfer” Addision Wesley Publishing Company, (1966).
5. Eckert, E. R. and Drake, R. M. Jr., “Analysis of Heat and Mass Transfer”, McGraw Hill Book Company, (1972).
6. Reid, R. C., Sherwood, J. M. and Prausnitz, T. K., “The Properties of Gases and Liquids”, McGraw Hill Book Company, (1972).





International Journal of Engineering
E-mail: office@ije.ir
Web Site: http://www.ije.ir