PROPOSED RELATIONSHIP TO DESIGN THE WAFFLE FLOOR UNDER HARMONIC VERTICAL LOADING
|
|
|
R. Jalili, M. M. Heydari and A. Fereydouni
|
|
|
( Received:
March 04, 2013
– Accepted: May 16, 2013 )
|
|
|
Abstract
The design codes of building are mainly related to the strength of the building and there are no specific codes for the
design of building with waffle floors for vibration sensitive equipment. The finite element model, ANSYS, is capable to
consider the effects of floor thickness, the size of the bays and stiffness of the columns for analyzing the vibration
of the waffle floors and vibration transmission along the waffle floor. Because the finite element analysis is time
consuming and it needs enough expertise for modeling, in this study, an approximate relationship is proposed to design
the waffle floor based on the comprehensive investigations of different effective parameters in the response of waffle
floor and the results obtained from finite element analysis. This proposed relationship comforts the designers of
industrial buildings and vibration sensitive equipment to attain a preliminary and appropriate outline to design the
waffle floor considering the effective parameters on the floor vibration.
|
|
|
Keywords
Waffle floor, Vibration, Harmonic loading, Finite element
|
|
|
چکیده
آييننامههاي مهندسي عمران براي طراحي ساختمانها، عمدتاً به مقاومت ساختمان براي تحمل بارهاي زلزله و استاتيكي پرداخته و آييننامه جامعي براي طراحي ساختمان با كف مشبك براي تجهيزات حساس به ارتعاش موجود نميباشد. مدل اجزاي محدود ANSYS براي تحليل ارتعاش در مركز كف مشبك و انتقال ارتعاش در امتداد كف مشبك ميتواند اثر ضخامت كف، اندازه دهانهها و سختي ستونها را لحاظ كند. با توجه به وقتگير بودن آناليز در نرم افزار اجزاي محدود و نياز به مهارت كافي براي مدل سازي، در اين مطالعه با بررسي جامع پارامترهاي مختلف موثر در پاسخ كف مشبك به بار هارمونيك و استفاده از نتايج بدست آمده از تحليل اجزاي محدود، فرمولي تقريبي براي طراحي كف مشبك پيشنهاد شده است. اين رابطه پيشنهادي، به طراحان ساختمانهاي صنعتي و دستگاههاي حساس به ارتعاش كمك ميكند كه طرحي اوليه و مناسب را براي طراحي كف مشبك با توجه به پارامترهاي موثر بر ارتعاش كف بدست آورند.
|
|
References
1. Jalili, R., "Vibration analysis of waffle floors under harmonic loads",
graduates Faculty Islamic Azad University: Bushehr Branch, (2011).
2. Petyt, M. and
Mirza, W., "Vibration of column-supported floor slabs", Journal
of Sound and Vibration, Vol. 21,
No. 3, (1972), 355-364.
3. Amick, H.,
Gendreau, M. and Bayat, A., "Dynamic characteristics of structures
extracted from in-situ testing", in SPIE's International Symposium on
Optical Science, Engineering, and Instrumentation, International Society for
Optics and Photonics, (1999), 40-63.
4. Howard, C. Q.
and Hansen, C. H., "Vibration analysis of waffle floors", Computers
& Structures, Vol. 81, No.
1, (2003), 15-26.
5. Leissa, A. W., "Vibration of plates", DTIC
Document,
(1969).
6. Howard, C. Q.,
Hansen, C. H. and Pan, J., "Power transmission from a vibrating body to a
circular cylindrical shell through passive and active isolators", The
Journal of the Acoustical Society of America, Vol. 101, (1997), 1479.
7. Reynolds, P. and Pavic, A., "Impulse hammer versus
shaker excitation for the modal testing of building floors", Experimental
Techniques, Vol. 24, No. 3,
(2000), 39-44.
|
|
|
|
|